Control box
Motor group
| Basic parameters PE510 | ||
| Power | 1500W | |
| Power supply | 220V ± 10% | |
| Control box size | 340*195*128 | |
| Motor size | 442*130*228 | |
| Reducer | Worm Gear Reducer (RV63) | |
| Motor working | S3 working system | |
| Maximum speed of motor unit | 150 rpm | |
| Motor set default speed | 125rpm | |
| Soft fast motor set rated torque | 74NM(2 times overload) | |
| Hard fast motor set rated torque | 96NM(2 times overload) | |
| Motor IP grade | IP54 | |
| Standard shielded wire length | 5m | |
| Rated working environment temperature | -10C-40C | |
| Maximum operating ambient temperature | -25C-60°C | |
| Limit | proximity switch + built-in absolute encoder | |
| Self-locking | electro-mechanical brake | |
| Maximum number of operations per day | 600 | |
| Control Panel Features | ||
| LCD | Display (Chinese and English) | |
| Door opening speed setting | stepless speed regulation | |
| Door closing speed setting | stepless speed regulation | |
| Opening deceleration interval setting |
|
|
| Closing deceleration interval setting |
|
|
| Automatic door closing delay time (seconds) | 0-240(0: Prohibit automatic door closing) | |
| Partial opening height (%) | Any height within limit | |
| Operation status display selection |
|
|
| Control Panel Extensions | ||
| Fault | tips in Chinese and English | |
| Data statistics |
|
|
| Historical Fault Query |
|
|
| Maintenance Reminder |
|
|
| jog mode |
|
|
| Reverse motor operation |
|
|
| Interface logic switching (NC/NO) |
|
|
| Low temperature antifreeze jitter function |
|
|
| Moment follow-up function |
|
|
| Control box interface | ||
| Networking communication physical interface | RS485 | |
| Safety protection signal 1 input | Emergency stop action | |
| Safety protection signal 2 input | reverse door opening action | |
| Automatic full door opening signal input |
|
|
| Partial door opening signal input |
|
|
| Single key cycle switch |
|
|
| Door opening limit (origin) switch input |
|
|
| Door Close Limit Switch Input |
|
|
| Interlock input |
|
|
| Programmable relay output | 2 groups | |
| Manual/automatic switching input |
|
|
| Emergency stop input |
|
|
| Can support limit type | motor built-in incremental encoder | |
| External absolute encoder | ||
| Mechanical limit | ||
| Proximity switch | ||
| Reducer ratio | 15 | 20 | 25 |
| Output torque (Nm) | 55 | 70 | 85 |
| Output Speed (RPM) | 166 | 125 | 100 |
| Motor power (KW) | 1.5KW | ||
| Motor Power | Reducer ratio | applicable area 114 drum | applicable weight 114 drum | Applicable area 140 drum |
applicable weight
140 drum |
|
1500W |
1:15 | Within24 | within 120KG | Within21 | within 90KG |
| 1:20 | Within30 | within 140KG | Within24 | Within130KG | |
| 1:25 | Within35 | within 160KG | Within30 | Within165KG |
A1 / 1.5KW control box