| Category | Hk Series | |
| Model Name | HK- 24 0-1000- A E 3 | |
| AC Input | Input Rating | 400V ac ± 15% |
| AC Input Connection | 3P + N + PE | |
| Max. Input Current (A) | 440 | |
| Frequency (Hz) | 45~65 | |
| Power Factor | >0.99 @ 50% or higher load | |
| Efficiency (%) | 9 5 | |
| DC Output | Output Voltage Range | 150 ~1000VDC |
| Max. Output Current | 200A | |
| Output Power Range(kW) | 240 kW | |
| Voltage Accuracy (%) | ± 0.5 | |
| Current Accuracy (%) | ± 1 | |
|
User Interface
& Control |
Display | 7 inch touch screen |
| Display | Emergency Stop | |
| Push Buttons | RFID system ISO / IEC14443A/B | |
| User Authentication | Charging process and status / Alarm and warning messages | |
| Communication | External | Ethernet/4G/3G |
| Internal | CANbus / RS485 | |
| Environmental | Operating Temperature (°C) | -30 ~ +50, power derating from 50 and above |
| Humidity (%) | 5 ~ 95 RH, non-condensing | |
| Altitude (m) | ≤2500 | |
| IP Level | IP55 | |
| Cooling method | Forced air cooling | |
| Mechanical | Dimension( L x W xH mm) | 75 0* 700 *1 860 |
| Weight(kg) | 392KG | |
| Cable Length(m) | 5(ccs2) | |
| Protection | Input Protection |
OVP, OCP, OTP, OPP, UVP, Residual current detection,
Surge protection, Cabinet-open detection (real door) |
| Output Protection | SCP, OVP, OCP, OTP, UVP, Residual current detection | |
| Regulation | Certificate | CE |
| Safety |
IEC 61851-1:2017, IEC 61851-23,IEC 61851-24,
IEC 61851-21-2 |
|
| Charging Interface | DIN70121 | |