RS485 Photoelectric Smoke Detector with Relay Output Fire Alarm

Model NO.
2001N
Working Mode
Relay Output
Certification
CE
Application
Indoor, Outdoor, Fire Detection
Transmission Mode
Wired
Highlight
White 4 Wire Smoke Detector, 24V Smoke Detector Wi
Contact Capacity
1A DC24V (No/Nc Optional)
Rated Operational Voltage
DC12~24V
Sound Pressure Level
Above 65dB
Humidity
≤95%
Work Temperature
-10°c~+50°c
Static Current
≤5mA
Alarm Current
≤5mA
Output
Sound & Light Alarm, Relay Output
Size
96*49mm(Diameter * Thickness)
Transport Package
Carton
Specification
D105mm, H50mm
Trademark
XHA
Origin
China
HS Code
8531100000
Production Capacity
500000pieces/Year
Reference Price
$ 122.40 - 150.30

Product Description

DC12/24V Industrial Control Equipment Fire Alarm Smoke Detector

RS485 Photoelectric Smoke Detector with Relay Output Fire Alarm





Introduction

4-Wire smoke alarm with relay output is common used for industrial control equipment, power cubicle, charging pile, alarm bell etc fire warning system. This smoke alarm has the characteristics of high sensitivity, stability and reliability, small power consumption and durability. Easy to install.


Parameters

 
Product Name smoke detector with relay output Rated operational voltage DC12~24V
Sound pressure level ≥65db Static current ≤300uA
Alarm current ≤90Ma Work temperature -10°C~+50°C
Output Sound&light alarm, relay output Humidity ≤95%.
Product standard  CE Dimension Φ105mm,H50mm


Functions
 

Work : Under normal circumstances, the indicator of the detector will flash about every 8 seconds. When the smoke concentration reaches or exceeds the alarm value, the red LED light of the detector remains bright, makes a sound, and starts the relay output.

When the smoke concentration in the environment returns to normal state, the detector automatically returns to normal state ( Alarm can automatically restore the state ).



Installation
 

The mounting hole size of the detector base is 49mm - 64.2mm. During installation,

two installation holes with a diameter of 5 mm were punched at a suitable position on the ceiling.

 

Smoke detectors are not suitable for use in :

A. Places where smoke is normally held ;

B. where there are large dust, water mist, steam, oil mist pollution and corrosive gas ;

C. ventilation speed is greater than 5m / s.




Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
RS485 Photoelectric Smoke Detector with Relay Output Fire Alarm

RS485 Photoelectric Smoke Detector with Relay Output Fire Alarm

 



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.

Conpany Profile
RS485 Photoelectric Smoke Detector with Relay Output Fire Alarm RS485 Photoelectric Smoke Detector with Relay Output Fire Alarm


Assembly Line
RS485 Photoelectric Smoke Detector with Relay Output Fire Alarm

Burn-in Room
RS485 Photoelectric Smoke Detector with Relay Output Fire Alarm

Quality Management System

Leave Your Message

 

✉ Contact Supplier