Category
|
HK Series
|
|
|
Model Name
|
HK-EJ-E-120-22QT- D1
|
|
|
AC Input
|
Input Rating
|
400 Vac ± 15%
|
|
Input voltage
|
400
|
|
|
AC Input Connection
|
3P + N + PE
|
|
|
Max. Input Current (A)
|
283A
|
|
|
Frequency (Hz)
|
45 ~ 65
|
|
|
Power Factor
|
>0.99
|
|
|
Input power
|
>90kw
|
|
|
DC Output
|
Output Voltage Range
|
50~500Vdc (CHAdeMO)
150~1000Vdc (CCS) 340~460Vac (type 2 AC) |
|
Max. Output Current
|
125A(CHAdeMO)/200A(CCS)/63A(type 2)
|
|
|
Output Power Range(kW)
|
DC 120kW + AC 22kw
|
|
|
Voltage Accuracy (%)
|
± 1
|
|
|
Current Accuracy (%)
|
± 1
|
|
|
User Interface
& Control |
Display
|
7 inch touch screen
|
|
Push Buttons
|
Emergency Stop
|
|
|
User Authentication
|
RFID ISO14443A (M1/MIFARE Card)
|
|
|
Display Information
|
Charging process and status / Alarm and warning messages
|
|
|
Communication
|
External
|
Ethernet/4G/3G
|
|
Internal
|
CANbus / RS485
|
|
|
Environmental
|
Operating Temperature (°C)
|
-30 ~ +50, power derating from 50 and above
|
|
Humidity (%)
|
5~95RH, non-condensing
|
|
|
Altitude (m)
|
≤2500m
|
|
|
IP Level
|
IP55
|
|
|
Cooling method
|
Fan cooling
|
|
|
Mechanical
|
Dimension(WxDxH mm)
|
750*690*1800
|
|
Weight(kg)
|
≤480
|
|
|
Cable Length(m)
|
5
|
|
|
Protection
|
Input Protection
|
OVP, OCP, OPP, OTP, UVP, Residual current detection, Surge protection, Cabinet-open detection (rear door)
|
|
Output Protection
|
SCP, OCP, OVP, LVP, OTP, Residual current detection
|
|
|
Regulation
|
Certificate
|
IEC 61851-1 , IEC 61851-23 , IEC 61851-21-2
|
|
Safety
|
CE
|
|
|
Charging Interface
|
CHAdeMO 1.2, ISO15118, DIN 70121
|
|