Item
|
Technical Requirements
|
|
Nominal Voltage
|
400VAC±15%
|
|
Input Current(MAX)
|
1100A
|
|
AC Input Frequency Range
|
40~60HZ
|
|
AC Input Mode
|
3P+N+PE
|
|
Rated Output Voltage
|
150~1000VDC
|
|
Rated Output Current
|
0~800A
|
|
Cooling Method
|
Force Air Cooling
|
|
Power Factor
|
>0.99
|
|
Efficiency
|
≥0.95(50% load or above)
|
|
Standby Consumption
|
≤0.1% @ nominal power
|
|
Voltage Error
|
≤±0.5%
|
|
Current Error
|
0.3A(Iout≤30A); ±1%( Iout≥30A)
|
|
Voltage Precision
|
≤±0.5%
|
|
Current Precision
|
≤±1%
|
|
Ripple Factor
|
Effective Value ≤±0.5%, Peak Value ≤±1%
|
|
Robust Protection
|
Protecting Functions: Input Overvoltage/undervoltage Protection, output overvoltage protection Input/output Overcurrent Protection, Short Circuit Protection, Emergency Stop Protection, RCD Protection, Earthing Protection, Self-checking after startup Protection,Output Wire Reversed Connected Protection
|
|
Charging Mode
|
Output Charging Interface: Pantograph
|
|
Communication Protocol
|
OCPP 1.6 (JSON) Optional
|
|
Internet/network
|
4G, Ethernet/ LAN/WIFI
|
|
IP Class
|
IP54
|
|
Operation Temperature
|
-30ºC~+55ºC
|
|
Noise
|
≤65dB
|
|
Humidity
|
5~95%
|
|
Environmental Protection
|
Meet 2011/65/EU
|