| FACP | Number of Detection Zones | Number of Sounder Outputs | Output Delay Settings |
| CK1004 | 4 | 1 | N/A |
| CK1008 | 8 | 2 | N/A |
| CK1016 | 16 | 4 | N/A |
|
1.2
Specifications
AC Power AC90-270 VAC, 5 0 Hz, 2.3 amps Wire size: minimum #14 AWG (2.0 mm 2 ) with 600V insulation Battery (lead acid only) Maximum Charging Circuit: Normal Flat Charge-27.6V @ 0.8 amp Maximum Charger Capacity: 18 Amp Hour batter Sound Output Device Circuits General Alarm Zones 1 through 16 Operation: All zones Class B Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum) Alarm Current: 15 mA threshold Short Circuit Current: 42 mA maximum Maximum Loop Resistance: 100 ohms End-of-Line Resistor: 4.7K, ½ watt Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone Standby Current: 7.26 mA Three Relays Output R elay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive) Non r esett a ble 2 4 VDC P o wer Max i mum ri p p le v o ltage: 1 0 m V R M S O p erat i ng V o lta g e n o m i nal 24 v o lts T o t al DC current avai l able from t h is ou t put i s up t o 5 00 mA Recommended maximum Sta n d b y cu r ren t i s 1 5 0 mA Input Circuits Sixteen i n put circui t s prov i de co n f i g ura t io n . In p u t circuits 1 throu g h 1 6 may b e u s ed as standard f i re alarm con t r o l p anel zones . A l l sixteen I n i t iati n g Device Circuits accept normally-open contact dev i ces and two-wire smoke detectors. Output Circuits • 24 V o lt R e se t t able Power O u tp u t 10 00 mA • 24 V o lt N onrese t tab l e Power O u t p ut 10 00 mA • 2 4 V ol t B a t te ry C ha r g er (u p t o 1 8 A H ba t ter i e s) • E IA - 48 5 P o r t ( in t er f ace s t o Ann u nci a t o rs, and Graph i c An n uncia t o rs and Rem o te Relay Mod u le) Sound ( Notification Appliance ) Circuits Four N o tificat i on A p plia n ce C i rcu i ts. Relays Three dry re l ays f o r system a l arm, system trouble and supervisory are provided standar d . Contacts are ra t ed 2.0 amps @ 30 V D C ( r esist i ve) and 2 . 0 amps @ 30 V A C (res i s t i ve). EIA-485 Port EIA-485 c o mpa t ib l e p o rt sup p or t s up to 1 0 d i f fere n t d evice addresses wh i ch can cons i s t o f Remote An n unc i ator s , Re l ay Mod u les, A nn u nciat o rs or Graphic An n unc i ators or a n y combina t ion o f the f o ur modu l es. Battery Charger Bat t ery C h a r ger wi l l cha r ge up t o 18 A H bat t er i e s. The CK1000 ca b inet h o l d s a maximum of 7 AH ba t t eries. The external box is req u ired t o h o ld 1 8 AH bat t eries. The cha r ger is rated for 5 00 mA maximum current. |