Conventional Fire Alarm Control Panel Manufacture Price

Model NO.
CK1004
Usage
Fire, Smoke
Certification
CE
Alarm Volume (within 1m)
≥100dB
Networking Mode
Alarm
Receive Frequency
485/232
Wiring Mode
Sub-Line System
Weight
7kg
Color
Red
Number of Zones
4
Primary AC
90-270VDC
Standby Battery
2*12V
Transport Package
Carton
Specification
37*440*100mm
Trademark
panel
Origin
China
HS Code
8531100000
Production Capacity
500000/Month
Reference Price
$ 117.00 - 162.00

Product Description

 
Conventional Fire Alarm Control Panel Manufacture Price
The CK1000 is a 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices.  The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits ( NAC, SOUND1-4), three standard Form- A  relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciator s and optional remote relay modules. The FACP is field programmable via the panel keypad.  It also supervises all wiring, AC voltage and battery level.

This series of panels are basically the same in application and operation, their differences are shown in Table 1-1. CK1000 will be described as the example in the following sections.

Table 1-1
FACP Number of Detection Zones Number of Sounder Outputs Output Delay Settings
CK1004 4 1 N/A
CK1008 8 2 N/A
CK1016 16 4 N/A

1.1   P roduct   Features
 
  1. 4,8,16 Class B   I n i t iat i ng Dev i ce   C i rcu i ts (I D Cs)
All   zones   accept   conventional   detectors and   any   normally open contact device
  1. Four  C l ass B Not i f i ca t i on A ppl i ance Circ u its ( N ACs)
  2. O ne F orm- A  Alarm   Relay
  3. O ne F o r m- A   T r o ub l e   Re l ay
  4. O ne F o r m- A  Super v isory Relay
  5. 3 . 0  am p s   of sys t em po w er
  6. Max 20 conventional detectors in one zone.
  7. Auto/Manual mode setting enable walk test.
  8. Each Zone can be disabled,
  9. Sound output can be disabled.
  10. Manual active sound output enabled.
  11. Able to report short and broken circuit of detection zones.
  12. Designed with standby batteries and space provision for two sealed lead-acid batteries.
  13. Testing and disable functions
    1.2   Specifications

    AC Power
    AC90-270  VAC, 5 0 Hz, 2.3 amps
    Wire size: minimum #14 AWG (2.0 mm 2 ) with 600V insulation
    Battery (lead acid only)
    Maximum Charging Circuit: Normal Flat Charge-27.6V @ 0.8 amp
    Maximum Charger Capacity: 18 Amp Hour batter
    Sound Output  Device Circuits
    General Alarm Zones 1 through 16
    Operation: All zones Class B
    Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum)
    Alarm Current: 15 mA threshold
    Short Circuit Current: 42 mA maximum
    Maximum Loop Resistance: 100 ohms
    End-of-Line Resistor: 4.7K, ½ watt
    Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone
    Standby Current: 7.26 mA
    Three Relays  Output
    R elay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)
    Non r esett a ble   2 4 VDC P o wer
    Max i mum ri p p le v o ltage: 1 0 m V R M S            O p erat i ng V o lta g e   n o m i nal 24 v o lts
    T o t al DC current avai l able from   t h is ou t put i s   up t o   5 00 mA
    Recommended maximum   Sta n d b y cu r ren t i s  1 5 0 mA
    Input Circuits
    Sixteen  i n put circui t s   prov i de co n f i g ura t io n . In p u t circuits 1 throu g h 1 6  may   b e   u s ed as standard f i re alarm con t r o l   p anel zones .   A l l sixteen  I n i t iati n g Device Circuits   accept   normally-open contact dev i ces and two-wire smoke detectors.

    Output Circuits
    •     24 V o lt R e se t t able Power O u tp u t 10 00 mA
    •     24 V o lt N onrese t tab l e   Power O u t p ut 10 00 mA
    •     2 4 V ol t B a t te ry   C ha r g er (u p t o 1 8 A H ba t ter i e s)
    •     E IA - 48 5   P o r t   ( in t er f ace s   t o   Ann u nci a t o rs,   and   Graph i c   An n uncia t o rs and Rem o te Relay Mod u le)

    Sound ( Notification Appliance ) Circuits
    Four N o tificat i on A p plia n ce   C i rcu i ts.

    Relays
    Three dry   re l ays   f o r system a l arm,   system trouble   and   supervisory   are   provided   standar d . Contacts are ra t ed 2.0 amps @ 30 V D C   ( r esist i ve)   and 2 . 0 amps   @ 30 V A C (res i s t i ve).

    EIA-485 Port
    EIA-485   c o mpa t ib l e   p o rt   sup p or t s   up   to   1 0   d i f fere n t   d evice   addresses   wh i ch   can cons i s t o f Remote An n unc i ator s , Re l ay Mod u les, A nn u nciat o rs or Graphic An n unc i ators   or a n y combina t ion o f the f o ur modu l es.

    Battery Charger
    Bat t ery   C h a r ger   wi l l   cha r ge   up   t o   18   A H   bat t er i e s.   The  CK1000   ca b inet   h o l d s   a   maximum   of   7   AH   ba t t eries. The external box  is req u ired t o   h o ld 1 8 AH bat t eries.   The cha r ger is rated   for 5 00 mA maximum   current.