48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving

Model NO.
DGG2-DC48V-12K
Usage
Room
Indoor Machine Noise
24-35dB
Certification
CE, IEC/Saso
China Energy Efficiency Standard
Level 1
Cooling/Heating
Cooling/Heating
Power Source
Solar
Power Type
DC
Condition
New
Weight Indoor
12.7kg
Weight Outdoor
36.5kg
Size Outdoor
900*400*610mm
AC Power
1 pH 200-240V, 50/60Hz
Suitable Room Square Meter
15-25 M
Cooling Capacity BTU
12000(3400-12911) BTU
Heating Capacity BTU
13648(3400-15989) BTU
Dehumidifier L/H
1.5
Refrigerant / G
R410A/ 980g
Compressor (Inverter DC)
Toshib/ Gmcc Rotary
Transport Package
Carton Box
Specification
823*360*300mm
Trademark
DEYE
Origin
China
HS Code
841582100
Production Capacity
500unit/Day
Reference Price
$ 430.20 - 473.40

Product Description

Product Description

48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving 48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving
Solar air conditioner have 2 kinds:

1: daily use solar panel power, evening use grid power electricity . We call it on grid solar air conditioner.

2: daily use solar panel power, evening use the electricity from the battery, normally 48V batteries. Solar panels supply electricity both to air conditioner and batteries.We call it off grid solar air conditioner.


Residential use 9000BTU, 12000BTU normally.
Commercial use 18000BTU, 24000BTU...depends on the room size.
On grid solar air conditioner only need solar panel and solar conditioner, of course some cables and connectors.
Off grid solar air conditioner need batteries extra.


48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving 48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving

Product Parameters

Technical data sheet

 
    9000btu 12000btu 18000btu 24000btu
    1HP(1.5TON) 1.5HP(1TON) 2HP(1.5TON) 3HP(2TON)
Model Number   DGWG2-ACDC-09K DGWG2-ACDC-12K DGWGV-ACDC-18K DGWGV-ACDC-24K
Power Supply 100%AC /100% DC / AC+DC AC power 1 Ph 200-240V,50/60HZ
DC power PV, series connection 80-350V DC
Specification Suitable Room Square Meter 15 Less 15-25 20-30 32-42
Outdoor Suitable Temperature ºC -15 to 56 -15 to 49 -15 to 49 -15 to 49
Indoor Setting Temperature ºC 16 to 32 16 to 32 16 to 32 16 to 32
Cooling Capacity Btu 9000(3400-12180) 12000(3400-12911) 17000(4100-18776) 22000(8500-24907)
Cool Consumption W 681(200-1120) 1096(210-1430) 1553(200-1994) 2009(470-2600)
Heating Capacity Btu 11942(2700-12191) 13648(3400-15989) 16377(4100-17742) 23000(10200-24566)
Heat Consumption W 1045(160-1162) 1143(170-1295) 1476(235-2080) 2360(410-2358)
EER(W/W) (BTU/W) 3.87/13.21 3.2/10.90 3.2/10.90 3.2/10.90
COP(W/W) (BTU/W) 3.35/11.42 3.40/11.6 3.2/10.90 3.20/10.90
Dehumidifier L/h 1.3 1.5 2.1 2.3
Refrigerant / g R410A/ 740g R410A/ 980g R410A/ 1180g R410A/ 1800g
Compressor (Inverter DC) TOSHIB/ GMCC Rotary TOSHIB/ GMCC Rotary TOSHIB/ GMCC Rotary PANASONI
2XRotary
Indoor Fan type BLDC BLDC BLDC BLDC
Indoor Fan Consumption W 18w 18w 40w 40w
Indoor Fan Speed (Turbo/High/Mid/Low) 1200/1100/1000/850 1300/1200/1100/950 1050/950/900/800 1350/1250/1150/1000
Indoor Fan Air Flow m3/h 485/434/382/305 536/485/434/357 971/864/808/700 1250/1120/1000/850
Indoor Noise Level dB(A) 41.7/38.8/33.0/31.6 44.6/42.6/36.3/35.0 44.3/41.5/38.8/36.8 51/50/47/42
Indoor Evaporator Row 2 2 2 2
Indoor Pipe Diameter Ф7 Ф7 Ф7 Ф7
Outdoor Fan type BLDC BLDC BLDC BLDC
Outdoor Fan Consumption W 40w 40w 55w 75w
Outdoor Fan Speed r/min 850 880 880 850
Outdoor Condenser Row 1 1 1.5 2
Outdoor Pipe Diameter Ф7 Ф7 Ф7 Ф7
Outdoor Fan Air Flow m3/h 1800 2000 2200 3320
Outdoor Noise level dB(A) ≤52 ≤52 ≤55 ≤58
Pressure Mpa (Gas/Liquid) 4.3/1.1 4.3/1.1 4.3/1.1 4.3/1.1
Connecting Pipe size (Gas/Liquid) Inch  3/8 1/4  3/8 1/4  1/2 1/4  1/2 1/4
Connecting Pipe Max Length M 15 15 20 25
Connecting Pipe Max Height M 8 8 10 10
Dimension Indoor unit / mm 790*210*280 790*210*280 1065×325×250 1065×325×250
Indoor Package/ mm 860*345*290 860*345*290 1169×405×366 1169×405×366
Indoor Weight (Gross/ Net) Kg 9.3/12.0 9.3/11.5 15.3/18 15.3/18
Outdoor unit 802×564×323 802×564×323 802×564×323 900×700×337
Outdoor Package 910*405*622 910*405*622 910*405*622 1006×418×755
Outdoor Weight (Gross/ Net) Kg 30.0/34.0 31.5/35.5 36/40.0 48.0/53.0
Loading QTY / 40 feet container 200 200 150 120
Certification As market request CE/ CB/ ETL CE/ CB/ ETL CE/ CB/ ETL CE/ CB/ ETL

 

Hybrid system FAB

Feature: Double power.

Advantage:Saving electricity, max 95% and average 70%,easy installation.

Benefit:Reduce electricity cost,and the same installation with usual AC.

Feature:Dynamic adjust and solar priority.

Advantage:The proporion of solar and electricity is dynamic,when solar down the electricity willup.When no sunshine it will be a full DC inverter by electricity.

 
Company Profile
48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving
48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving
48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving
48VDC off Grid 12000BTU Heating and Cooling Wall-Mounted Solar Air Conditioner 90%Saving
 

Leave Your Message

 

✉ Contact Supplier